No Heat in Winter: Safety First
If you smell gas, leave the house immediately and call the gas utility from outside. Do not light matches or flip switches. A suspected carbon monoxide alarm also means fresh air first and a call for help second.
If the boiler is simply cold, check the thermostat, the power switch and the water pressure gauge, then call the line. Dispatch will ask what the boiler displays and when it last ran.
What the Symptom Points To
Boilers give clues before they fail. This table covers common ones.
| Symptom | Likely cause | Urgency |
|---|---|---|
| No heat, boiler silent | Power, thermostat, ignition or gas supply | High in cold weather |
| Radiators cold at the top | Air in the system | Medium |
| Banging or kettling noise | Scale or low flow | Medium |
| Water pooling at the base | Leak at a joint, valve or the vessel | High |
| Pressure falls below normal | Leak or a failing expansion tank | High |
| Pressure relief valve discharging | Overpressure or a failing valve | High |
The diagnosis on site is what settles the repair.
No heat tonight?
Call dispatch and tell them what the boiler is doing.
What We Repair on Hydronic Heating
Many homes in the Chicago area heat with hot water through radiators or baseboard. These are the parts we work on most.
Ignition and controls
Thermostats, aquastats, ignition modules and flame sensors fail and stop the boiler from firing.
Circulator pumps and zone valves
A weak circulator or a stuck zone valve leaves part of the house cold while the boiler runs.
Expansion tanks and relief valves
An expansion tank that has lost its air charge lets pressure climb until the relief valve opens.
Bleeding and pressure
We bleed trapped air, set the pressure and check for leaks that cause repeated pressure loss.
Permits and Licensed Work
The City of Burbank Building Department says a permit is required for construction or alteration of plumbing, and contractors must be licensed. The office is at 6530 W 79th Street, and the phone is 708-599-5500, option 2.
A boiler replacement or a change to piping and venting can involve the permit process. Dispatch explains what applies to your repair.
Water Quality and Boiler Life
Chicago, which supplies water to Burbank through the district, reported hardness of 134 to 143 mg/L as calcium carbonate in its 2013 lab reports. That is a 2013 figure, so confirm the current number with the utility.
A closed hydronic system uses the same water for years, so scale is less of an issue than in a water heater. A new boiler or a system that has been drained and refilled takes fresh water and needs flushing and treatment.
Keep the Boiler Healthy Between Calls
A little maintenance cuts the number of no-heat calls.
- Have the boiler serviced before the heating season starts
- Check the pressure gauge monthly and note any steady drop
- Keep the area around the boiler clear of storage
- Bleed radiators at the start of winter
- Replace carbon monoxide alarm batteries and test the unit
If the pressure keeps dropping, call. A hidden leak in the system needs a plumber, not just a top-up.
What Affects Boiler Repair Pricing
The price depends on the part and how long diagnosis takes. Dispatch quotes by phone and confirms the number on site.
If the boiler is near the end of its life we say so before approving a large repair.
Boiler Rules in Illinois
Boiler construction follows the ASME Boiler and Pressure Vessel Code, a national standard, and Illinois regulates boilers through the Office of the State Fire Marshal. Ask dispatch whether a commercial boiler at your address falls under that oversight.
Gas piping and venting follow NFPA 54. If you smell gas, leave the building and call the gas utility first.
Boiler Repair FAQ
Yes. The line is open 24/7, and dispatch schedules no-heat and boiler leak calls at any hour. Same-day appointments are offered when a crew is available.
A leak in the system, a leaking relief valve or a failed expansion tank can cause it. A plumber finds the source rather than just adding water.
Leave the house, avoid switches and flames, and call the gas utility from outside. Then call a plumber once the gas company has made the house safe.
Air in the system, a stuck zone valve or a weak circulator may be the cause. Bleeding the radiator often helps with air.
It depends on the cost of the repair relative to the boiler's age and condition. We give an honest assessment before you approve a large repair.